Secure estates

Defence and Security

A defence estate is concrete and steel that was built to last and is now being asked to last longer: hardened structures, bunkers, hangars, aprons, piers, magazines and the post-war offices and accommodation around them.

  • Level 4 UKCSS Operator
  • Interpreted and reported for engineers
  • Oxford based, UK and Europe
NDTScan operative in a harness scanning a concrete wall with ground penetrating radar

NDTScan surveys those structures with UK personnel under the establishment's security and access rules, reports to the estate's engineer, and keeps the data where the establishment says it should be kept. It does not inspect vehicles, vessels or weapons; that is the work of the services' own engineering organisations.

What NDTScan surveys on a secure estate

  • Hardened structures and bunkers. Wall and roof thickness, reinforcement layout and voids by GPR with the antenna matched to thick, dense concrete; condition by ultrasonics; openings and services located before any penetration is made.
  • Hangars, aprons, runways and hardstandings. Slab thickness, reinforcement, dowels and voids beneath pavement concrete; floors scanned before docking, anchors and plant are fixed through them. See aerospace and aviation.
  • Piers, jetties and sea defences. Marine steel gauged, marine concrete scanned, and the structure below water inspected by ROV and sonar. See maritime and underwater assets.
  • Legacy buildings. Offices, accommodation, stores, medical and training buildings of the late 1950s to mid 1990s checked for RAAC plank by plank and assessed for condition.
  • Tanks, pipework and plant. Fuel and water infrastructure gauged for remaining thickness; see thickness testing and corrosion mapping.
  • Perimeters and ground. Services, ducts, voids and buried structures located beneath roads, compounds and fence lines before works, by cart and by vehicle-mounted radar for long runs.
Specialist scanning a concrete wall with ground penetrating radar
A thick wall scanned with a low-frequency antenna. The reinforcement and the thickness come from the same pass.

Working under security rules

Surveys are carried out by UK personnel, with vetting, passes and escorts arranged in advance to the establishment's requirements, and the equipment declared and cleared before it arrives. Photography, drone flights and data handling follow the establishment's rules: where imagery is not permitted, findings are recorded on drawings alone; where data must stay on site, it stays on site; where a flight is not permitted, the roof is surveyed from access equipment. Nothing is promised that the security regime does not allow. Instruments are calibrated by UKAS-accredited laboratories where the work requires it, and the work follows the relevant ISO and BS EN standards with the standard stated in the report.

Methods

Concrete scanning with GPR, Ferroscan, pulse velocity and pulse echo, cover, carbonation and half-cell; ultrasonic thickness testing and corrosion mapping of steel; drone and LiDAR records where permitted; inspection-class ROV below water. Weld inspection by phased array, magnetic particle or radiography, where a project specifies it, is arranged through specialist partners who meet the establishment's clearance requirements and coordinated by NDTScan.

What the engineer receives

Scaled plans of every scanned or gauged area with the findings against each element, depth and thickness tables with the tolerance that applied, the equipment and standard used, and the confidence attached to each finding with what it must not be relied on for, delivered in the format and through the channel the establishment specifies, and suitable for secure archiving and audit. The interpreted report follows within an agreed number of working days.

Who instructs NDTScan

Defence estate and infrastructure organisations and their consulting engineers, the facilities providers running secure sites, police, prison and critical national infrastructure estates, and the contractors working on them under the same rules. NDTScan attends from Oxford anywhere in the UK, usually within one to two working days and same day where the diary allows, with the vetting and access lead time the site requires.

Do you offer scanning services for MOD bases, bunkers or hardened structures?

Yes: wall and roof thickness, reinforcement and voids in hardened concrete, slabs and runways, piers and legacy buildings, with vetting and passes arranged in advance.

Can you work within restricted zones or alongside military personnel?

Yes, with escorts and the site's rules governing the visit, and the equipment declared and cleared beforehand.

What NDT methods are used on defence estates?

Ground penetrating radar, Ferroscan, ultrasonic pulse velocity and pulse echo, ultrasonic thickness gauging, drone and LiDAR where permitted, and ROV below water. Weld inspection methods are arranged through cleared specialist partners where a project specifies them.

Do you provide documentation suitable for secure archiving and audit?

Yes. Reports and data are delivered in the format and through the channel the establishment specifies, with the method, equipment and calibration recorded for audit.

Questions we are asked

Can you inspect sensitive or classified infrastructure without disruption?

Yes, under the establishment's security, access and data-handling rules, with battery-powered instruments that read from the surface and leave the structure in service.

Tell us about the structure.

A postcode, the element in question and what you need to do to it is enough to start. Every survey is quoted on the structure, the access and the reporting required.