RAAC surveys in Bollington. The UK's reference point for RAAC.

RAAC Surveys Bollington | Identification and Assessment | NDTScan

RAAC identification, condition assessment and reporting to IStructE guidance across Bollington, Cheshire and the surrounding area. NDTScan attends from its Oxford base, anywhere in the UK.
Cracked RAAC roof planks photographed during an NDTScan survey

Overview

RAAC surveys in Bollington are carried out by NDTScan, the UK's specialist in the identification and analysis of reinforced autoclaved aerated concrete. The planks were installed in Cheshire buildings for nearly forty years, mainly in flat and shallow-pitched roofs, and they are now well beyond the design life their manufacturers assumed. Identifying them is the first step; understanding their condition is the one that matters.

The Department for Education's list of education settings with confirmed RAAC, published in February 2024, includes 2 settings in Cheshire East, among them The Macclesfield Academy and Sandbach School. The Department of Health and Social Care's list of hospital sites with confirmed RAAC includes Countess of Chester Hospital, Leighton Hospital and Warrington General Hospital in Cheshire. Those are the buildings that made the published lists, which cover schools, colleges and NHS sites. They are named here as evidence that the construction is present in Cheshire, not as NDTScan projects. Around Bollington the same roof and floor planks are in council buildings, housing, leisure centres, retail units and industrial sheds that nobody has counted.

A RAAC survey from NDTScan starts with identification. Ground penetrating radar separates aerated planks from dense concrete, hollowcore and timber decks plank by plank, and the reinforcement pattern, transverse bars and plank widths confirm the reading without opening the roof. Condition comes next: cracking, deflection, end bearing, water staining, corrosion and previous repairs are recorded for each plank, and the findings are classified in line with IStructE guidance so the Bollington owner can see at once which elements need action, which need monitoring and which are sound.

One rule applies to every RAAC survey in Bollington. No remediation, propping, strengthening or replacement should be designed until each plank has been identified and its condition recorded. Some of the most expensive RAAC decisions in the UK were taken on roofs that had never been properly surveyed. The survey is the cheapest part of getting the decision right, and NDTScan will say so to every Bollington client.

Scan before you repair. That is the standing advice for every Bollington client, and the reason NDTScan reports what the concrete contains before anyone specifies what to do about it.

Services Available in Bollington

  • RAAC Identification Survey GPR based, plank by plank identification of reinforced autoclaved aerated concrete in roofs, floors and walls across Bollington. Confirms what the element is made of without opening it up, and records plank widths, reinforcement and bearing details as evidence.
  • RAAC Condition Assessment Plank level inspection of confirmed RAAC for cracking, deflection, bearing length, water ingress, corrosion and previous repairs, classified in line with IStructE guidance. Reported so a Cheshire engineer or estates team can act on it directly.
  • RAAC Management and Reinspection Monitoring regimes, reinspection intervals and management plans for RAAC that is being kept in service, plus expert input where a Bollington owner needs an independent second opinion on a survey or a remediation proposal.

RAAC in and around Bollington

Instructions in and around Bollington follow the RAAC lifecycle. Identification surveys where the construction of a flat or shallow roof is uncertain. Condition assessment of planks already known to be RAAC. Risk classification to IStructE guidance to support closure, propping or continued use decisions. Management plans and reinspection for planks kept in service. Independent review where a Cheshire owner has been given a survey or a remediation quote and wants a second opinion before spending. NDTScan works for the Department for Education, the Department of Health and Social Care and the Office of Government Property funded bodies as well as private owners, and attends Bollington from its Oxford base.

NDTScan also provides RAAC surveys in Warrington, Chester, Crewe, Ellesmere Port, Runcorn and Widnes and the rest of Cheshire. The rest of the region is covered from the North West RAAC surveys page, and the service itself is described on the RAAC surveys page.

About NDTScan

NDTScan is a specialist non-destructive testing company based in Oxford and led by Neil Smuts, author of The RAAC Book. It is the UK's specialist in the identification and analysis of reinforced autoclaved aerated concrete, and a Level 4 UKCSS Operator, the first in the UK to achieve that certification. RAAC surveys in Bollington sit alongside the company's concrete scanning and structural condition survey work, and every report is written to a standard suitable for engineering acceptance, insurers and dispute work.

Bollington RAAC Services

02080
888 724

info@ ndtscan.com

It is. NDTScan travels anywhere in the UK for RAAC work, and Bollington is reached from the Oxford base like every other town in Cheshire. The survey team, the equipment and the reporting are the same wherever the building is.
Yes. Ground penetrating radar reads the internal structure of the plank without any opening up, and the difference between aerated and dense concrete is clear in the data. Where the ceiling finish or roof covering hides the planks, NDTScan works from whichever face is accessible. For a Bollington building that means identification with no damage to the fabric.
Each confirmed plank is inspected for cracking, deflection, bearing length, water ingress and staining, corrosion of the reinforcement, previous repairs and any signs of overloading or cutting. The findings are classified in line with IStructE guidance so the Bollington owner can see which planks need immediate action, which need monitoring and which are sound.
Anything with a flat or shallow-pitched roof built between the late 1950s and the mid 1990s: schools, colleges, hospitals, clinics, council offices, leisure centres, community halls, housing blocks, retail units and industrial sheds. Across Cheshire the education and NHS estates have been counted; the rest of the stock has not, and that is where most uninspected RAAC now sits.
NDTScan's own specialists, not a subcontractor. The company is the UK's specialist in RAAC identification and analysis, and the person who reads the radar data and classifies the planks is a specialist in this material. The Bollington report is the interpretation, not a set of marks on a ceiling.

Our NDT Process - Simplified

How NDTScan Delivers Clarity, Confidence, and Compliance

Initial Scope Consultation

We start by understanding your asset, its environment, and your inspection goals. Whether it's structural integrity, corrosion mapping or defect detection, our team tailors a solution that fits.

Advanced NDT Scanning

Using industry-leading equipment, including Trimble, Leica, DJI drones, and GPR systems, we perform detailed non-intrusive testing with minimal disruption.

Data Reporting & Analysis

You receive comprehensive, plain-English reports backed by high-resolution imagery, 3D models, and annotated scan maps. Data is delivered fast, often within the same week.

Recommendations & Support

Beyond inspection, we guide your next steps, from remedial works to structural interventions or re-inspections. We’re partners, not just service providers.

Precision Scanning. Proven Results. Trusted Nationwide.

Our performance protects your assets. Our technology leads the way. Our insight helps you decide.

We deliver specialist non-destructive testing (NDT) that helps you avoid risk, cut cost, and gain absolute clarity, across infrastructure, utilities, construction, marine and more.

Why Choose NDTScan

Changing the way industries think about inspection and assurance.

Proven, Compliant Technology

Our scanning systems are smart, secure, and fully compliant with UKAS, ISO 9712, and sector safety protocols. We bring the right tech to every job, no compromise.

Highly Skilled Team

Every NDTScan technician is certified, trained, and experienced in real-world environments, from rail tunnels to marine piles. You're in expert hands.

Certified, Auditable Results

We deliver UKAS-traceable reporting and standards-led inspection workflows, ideal for clients under CDM, Utilities, and Infrastructure compliance frameworks.

Support When You Need It

From urgent site visits to post-scan guidance, our team is on hand to support you, because clarity shouldn't wait until Monday.

Bollington RAAC Survey FAQs

Frequently Asked Questions.

Common questions about RAAC identification, condition assessment and reporting in Bollington and across Cheshire, answered by NDTScan.
It is. NDTScan travels anywhere in the UK for RAAC work, and Bollington is reached from the Oxford base like every other town in Cheshire. The survey team, the equipment and the reporting are the same wherever the building is.
Yes. Ground penetrating radar reads the internal structure of the plank without any opening up, and the difference between aerated and dense concrete is clear in the data. Where the ceiling finish or roof covering hides the planks, NDTScan works from whichever face is accessible. For a Bollington building that means identification with no damage to the fabric.
Each confirmed plank is inspected for cracking, deflection, bearing length, water ingress and staining, corrosion of the reinforcement, previous repairs and any signs of overloading or cutting. The findings are classified in line with IStructE guidance so the Bollington owner can see which planks need immediate action, which need monitoring and which are sound.
Anything with a flat or shallow-pitched roof built between the late 1950s and the mid 1990s: schools, colleges, hospitals, clinics, council offices, leisure centres, community halls, housing blocks, retail units and industrial sheds. Across Cheshire the education and NHS estates have been counted; the rest of the stock has not, and that is where most uninspected RAAC now sits.
NDTScan's own specialists, not a subcontractor. The company is the UK's specialist in RAAC identification and analysis, and the person who reads the radar data and classifies the planks is a specialist in this material. The Bollington report is the interpretation, not a set of marks on a ceiling.