Following a severe fire at a commercial premises in Oxfordshire, the structural engineer required detailed scanning of fire damaged buildings to assess the integrity of the remaining concrete structure. NDTScan was commissioned to conduct non-destructive testing surveys to locate reinforcement, measure concrete cover depths and identify delamination within fire-affected slabs and columns. The data was essential to inform the structural appraisal and determine whether repair or demolition was the safest course of action.
Fire exposure causes concrete to spall, crack and lose compressive strength, particularly when temperatures exceed 300°C. Visual inspection alone cannot reveal the extent of internal damage to reinforcement or the depth of heat-affected concrete. The client needed to establish the position and condition of steel reinforcement within heavily fire-damaged columns and floor slabs, but could not rely on original drawings due to discrepancies found during initial investigation.
Conventional cover meters were ineffective in areas where surface concrete had spalled or where high temperatures had altered the magnetic properties of the steel. Access was restricted due to structural instability, and the client required rapid survey mobilisation to maintain the programme for the insurance assessment and enable early decision-making on remediation strategy.
NDTScan deployed ground penetrating radar using a Proceq GP8800 system fitted with a 2.6 GHz antenna to map reinforcement layout and identify subsurface voids and delamination across fire-affected slabs and beams. Cover depth measurements were taken at 100 mm grid intervals and processed to produce detailed reinforcement maps. Where GPR signal attenuation occurred due to moisture ingress or charred concrete, ultrasonic pulse velocity testing was conducted using a Proceq Pundit PL-200 to assess concrete quality and detect areas of reduced wave transmission indicative of thermal damage.
All surveys were conducted in accordance with BS 1881-203 and the client's CDM-compliant site safety plan. Data was georeferenced and overlaid onto site plans, with anomalies flagged for structural review. Our UKCSS-accredited technicians worked alongside the demolition contractor to ensure safe access and complete coverage of critical structural elements within a two-day site programme.
NDTScan provided CAD drawings showing reinforcement positions, cover depths and zones of probable thermal damage across 450 m² of fire-affected structure. The survey identified three columns where reinforcement cover had been reduced to less than 15 mm due to spalling, and highlighted delamination exceeding 40 mm depth in two slab areas. This data enabled the structural engineer to specify targeted demolition of compromised elements while retaining sections of the structure that remained serviceable.
The client avoided unnecessary full demolition, reducing waste removal costs and programme time. The non-destructive approach eliminated the need for destructive breakouts in unstable areas, improving site safety and accelerating the insurance claim process.
NDTScan is UKCSS accredited and provides UKAS-traceable concrete scanning, GPR surveys and ultrasonic testing for structural assessments following fire damage. Contact our team for rapid mobilisation and nationwide coverage, with reports delivered to support your structural appraisal and remediation planning.